LY1-C40

LY1-C40/3+1

LY1-C40/3S+1

Modular surge arrester for use in TT and TN-S systems ("3+1" circuit) with floating remote signaling contact.


Cover the following types

LY1-C40/1+1, LY1-C40/1S+1, LY1-C40/3+1, LY1-C40/3S+1

LY1-C40/1, LY1-C40/1S, LY1-C40/2, LY1-C40/2S, LY1-C40/3, LY1-C40/3S, LY1-C40/4, LY1-C40/4S


n Prewired complete unit consisting of a base part and plug-in protection modules

n High discharge capacity due to heavy duty zinc oxide varistors/spark gaps

n High reliability due to "temperature-controlled" SPD monitoring device


Technical data

Type

LY1-C40/3S+1

SPD according to EN 61643-11 / IEC 61643-11

type 2 / class II

Nominal a.c. voltage Un

230 / 400 V AC (50/60 Hz)

Max. continuous operating a.c. voltage [L-N] Uc

275 V AC (50/60 Hz)

Max. continuous operating a.c. voltage [N-PE] Uc

255 V AC (50/60 Hz)

Nominal discharge current (8/20μs) In

20 kA

Maximum discharge current (8/20μs) Imax

40 kA

Voltage protection level Up

1,5 kV (L-N, N-PE)

Follow current extinguishing capability [N-PE] Ifi

100 Arms

Response time tA

25 ns (L-N)

Response time [N-PE] tA

100 ns

Max. mains-side over-current protection

125 A gL/gG

Short-circuit current rating ISCCR

25 kA

Temporary overvoltage (TOV) (UT) - Characteristic

335 V / 5 sec. - withstand [L-N]

Temporary overvoltage (TOV) (UT) - Characteristic

440 V / 120 min. - safe failure [L-N]

Temporary overvoltage (TOV) [N-PE] (UT) - Characteristic

1200 V / 200 ms - withstand

Residual current - Leakage current at Uc IPE

0,5 mA

Humidity range

5% ... 95%

Range of operating temperatures TU

-40°C ... +70°C

Atmospheric pressure and altitude

80k Pa ... 106k Pa,

-500 m ... 2000 m

Operating state / fault indication

Green ok / Red defect

Number of ports

One port

Cross-sectional area (min.)

1.5 mm2 solid /flexible

Cross-sectional area (max.)

35 mm2 stranded / 25 mm2 flexible

For mounting on

35 mm DIN rail acc. to EN 60715

Enclosure material

thermoplastic

Place of installation

indoor installation

Degree of protection

IP 20

Capacity

4 module(s), DIN 43880

Approvals

-

Type of remote signalling contact

changeover contact

a.c. switching capacity

250V / 0.5 A

d.c. switching capacity

250V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A

Cross-sectional area for remote signalling

terminals

max. 1.5 mm2 solid / flexible

Application system

SPD is connected to

TN and TT system

The prospective short-circuit current 

according to 7.1.1 d5 of IEC 61643-11

5 A

Remote signalling alarming mode

Normal: closed;

failure: open-circuit

Acessibility

Inaccessible

Protection fuction

Overcurrent


Circuit diagram



Drawings


Installation, Usage and Maintenance


This product can only be installed and maintained by qualified professionals. The installation position cannot be touched by hands. Ensure that it is unpowered and check whether the SPD is all right before installation. If there’s damage or the display window is red, the SPD cannot be used any more; if the window is green, the SPD is normal.

The installation of SPD should be based on Fig. 3 IEC 60364-5-53. The cross-sectional area of ground wire should not be less than 4 mm2, and the length of total lead not more than 0.5m.

The minimum distance from any earthed conductive surface at which the SPD can be installed is 8mm.

Connection of remote signalling alarm: the SPD is provided with remote signalling interfaces (NC, COM and NO, normally closed), applicable for remote centralized monitoring or alarm.

After the connection, check if the module is fitted in. If so, NC and COM are closed; if not, repress the module.


Wiring Diagram


Type

Picture

Picture Number

Connection

LY1-C40/1

LY1-D20/1

Circuit diagram

4027511-01

1+0

Drawings & Nameplate

4027511-02

Wiring diagram

4027511-03

LY1-C40/1S


LY1-D20/1S


Circuit diagram


4027512-01

1+0

Drawings & Nameplate

4027512-02

Wiring diagram

4027511-03

Type

Picture

Picture Number

Connection

LY1-C40/1+1


LY1-D20/1+1


Circuit diagram

4027513-01

1+1

Drawings & Nameplate

4027513-02

Wiring diagram

4027513-03

LY1-C40/1S+1


LY1-D20/1S+1

Circuit diagram

4027514-01

1+1

Drawings & Nameplate

4027514-02

Wiring diagram

4027513-03


Type

Picture

Picture Number

Connection

LY1-C40/2


LY1-D20/2

Circuit diagram

4027521-01

2+0

Drawings & Nameplate

4027521-02

Wiring diagram

4027521-03

LY1-C40/2S


LY1-D20/2S

Circuit diagram

4027522-01

2+0

Drawings & Nameplate

4027522-02

Wiring diagram

4027521-03


Type

Picture

Picture Number

Connection

LY1-C40/3


LY1-D20/3

Circuit diagram

4027531-01

3+0

Drawings & Nameplate

4027531-02

Wiring diagram

4027531-03

LY1-C40/3S


LY1-D20/3S

Circuit diagram

4027532-01

3+0

Drawings & Nameplate

4027532-02

Wiring diagram

4027531-03


Type

Picture

Picture Number

Connection

LY1-C40/3+1


LY1-D20/3+1

Circuit diagram

4027533-01

3+1

Drawings & Nameplate

4027533-02

Wiring diagram

4027533-03

LY1-C40/3S+1


LY1-D20/3S+1

Circuit diagram

4027534-01

3+1

Drawings & Nameplate

4027534-02

Wiring diagram

4027533-03


Type

Picture

Picture Number

Connection

LY1-C40/4


LY1-D20/4

Circuit diagram

4027541-01

4+0

Drawings & Nameplate

4027541-02

Wiring diagram

4027541-03

LY1-C40/4S


LY1-D20/4S

Circuit diagram

4027542-01

4+0

Drawings & Nameplate

4027542-02

Wiring diagram

4027541-03

Back: LY1-B100

Next: LY1-D20